Condensate pumps, condensate, Sahara, Condensate removal pump

Condensate Pumps

Condensate Pumps and Electronic Switches

SAHARA_2

SAHARA

The SAHARA is a solid state electronic condensate removal system designed to fi t neatly inside even the smallest wall mounted air conditioners.
The SAHARA’s electronic reservoir sensing unit eliminates all worries about positioning. This versatile
little unit is so easy-going that you’re spoiled for choice.

  • UL Approved
Technical Data:
Power supply:
120/240 V, 50/60 Hz Auto sensing
Power consumption:
16 W max., 0.25 when idle
Alarm relay:
5 A, 30 VDC, 250 VAC Break on fault
Capacity:
3.17 US gal/h
Discharge head:
>65 ft vertical, >328 ft horizontal
3.28 ft suction
Ambient temp:
32° F to 104° F
Material:
Flame retardant ABS - UL94 5 VA
Discharge tube:
1/4“ ID
Supply cable lenght: 5 ft
Pump-sensor-tube: Lenght 5 ft, dia. 1/8“
Dimensions pump:
5.3“ x 1.8“ x 1.26“
Dimensions sensor: 1.8“ x 1.4“ dia.

Part No. 4678482


Download:
  > Manual > Installation Video



KAROO_2

KAROO

The KAROO drain pan pump is a
submersible condensate removal pump designed to automatically remove condensate water
from refrigerated cases, dehumidifi ers, fan coils and air conditioning systems. The pump is intended to be
installed within a collection tray inside the equipment. The water level is measured by an Electronic Energy
Control System (EECS) that controls the operation of the pump via the fully-encapsulated circuitry.

  • UL Approved
Technical Data:
Power supply:
120/240 V, 50/60 Hz Auto sensing
Power consumption: 16 W max., 0.25 when idle
Alarm relay:
5 A, 30 VDC, 250 VAC Break on fault
Capacity: 3.17 US gal/h
Discharge head:
>65 ft vertical, >328 ft horizontal
3.28 ft suction
Ambient temp: 32° F to 104° F
Material: Flame retardant ABS - UL94 5 VA
Discharge tube: 1/4“ ID
Dimensions:  6.3“ x 1.7“ x 1.3“

Part No. 4678512

Download:   > Manual > Installation Video


YUMA_2

YUMA

The YUMA condensate pump is easy to fit  and easy to maintain – the pump is made for installers. Speedy fitting is assured with the YUMA. Completely
automatic operation is enhanced by the intelligent Electronic Energy Control System (EECS) circuitry to guarantee quiet starting and stopping, as well as power control to regulate the amount of energy required toremove the condensate.

  •  UL Approved
Technical Data:
Power supply: 120/240 V, 50/60 Hz Auto sensing
Power consumption:
16 W max., 0.25 when idle
Alarm relay:
5 A, 30 VDC, 250 VAC Break on fault
Capacity:
3.17 US gal/h
Discharge head:
>65 ft vertical, >328 ft horizontal
3.28 ft suction
Ambient temp:
32° F to 104° F
Material: Flame retardant ABS - UL94 5 VA
Discharge tube: 1/4“ ID
Dimensions: 6.9“ x 1.8“ x 1.6“

Part No. 4678520

Download:   > Manual > Installation Video


gobi_220_02

GOBI

The GOBI is a condensate discharge module designed to be fitted below modern wall mounted airconditioners. The new design and technology makes the GOBI our most innovative water sensing system ever. The GOBI pump incorporates the Electronic Energy Control System (EECS), microprocessor control delivers a smooth unobtrusive pump operation.

  • UL Approved

 

 
Technical Data:
Power supply: 120/240Vac, 50/60Hz Auto sensing
Power consumption: 16W max., 0.25W when idle
Alarm relay: 5A, 30Vdc, 250Vac Break on fault
Capacity:
12 litres/hour max. (3.17 US gal/h)
Maximum head: Vertical >20m (65 ft), Horizontal >100 (328 ft)
Suction 1 m max. (3.28 ft)
Ambient temp: 0 - 40°C
Water temp: 25°C max.
Material: Flame retardant ABS  UL94 5VA
Discharge tube: 6mm (1/4”) ID
Dimensions: 286 x 61 x 53mm (11.3” x 2.4” x 2”)

Part No 4678538

Download:
> Instruction manual   > Installation video



AquaSwitch

AQUASWITCH

The AQUASWITCH is an electronic water switch for valves, pumps and alarms.

The AQUASWITCH is a small controller with a sensitive electronic circuit encapsulated inside.

Constructed for all applications where a reliable switch is needed to control or indicate the presence of water.

Technical Data:
Voltage: 24 V AC/DC
Max. switched relay current: 5 A
Relay switch-off delay: 2.5 +/- 0.5 seconds
Ambient temperaturerange: 32 °F to 167 °F
Water level for switching relay: 0 +/-1/5" (depends on water quality)


AQUASWITCH-24-UL   
Part No. 4679152


Download:   > Manual


LAC_Universal

LAC UNIVERSAL

The LAC UNIVERSAL is an electronic controller for outdoor fans on heat pumps and cooling-only air conditioners.

By controlling the speed of the fan in changing ambient temperatures this electronic controller brings benefits to all air conditioning installations.

 

Technical Data:
Fan motor voltage: 110 - 120 V, 60 Hz
208 - 240 V, 60 Hz
Max. continuous fan motor current: 2 A
Max. fan motor start current: 5 A
Controller max. ambient temperature: 122 °F
Condensing temperature control range: 86 °F to 140 °F
Fan minimum speed adjustment range: 0 - 100 % (factory set to approx. 30 %)
Heat pump solenoid valve voltage: 24 VAC - 250 VAC

Description Voltage Part No.
LAC UNIVERSAL-115-60-UL 110 - 120 V, 60 Hz
4679306
LAC UNIVERSAL-230-60-UL 208 - 240 V, 60 Hz 4679314

Download:   > Manual


LAC_Extreme

LAC EXTREME

The LAC EXTREME is a Low Ambient Controller for all air cooled condensing units in air conditioning and refrigeration units with fan motor.

The intelligent logic programmed into these high specification controllers decides the correct speed for the outdoor fan, whether the fan should stop and for how long, to provide the maximum system efficiency.

Technical Data:
Fan motor voltage: 110 - 120 V, 60 Hz
208 - 240 V, 60 Hz
Fan motor running current: 4 A max.
Ambient temperature: -22 °F to 122 °F
Set point condensing
temperature range: 86 °F to 140 °F
Input voltage from reversing valve: 24 - 240 V, 60 Hz


Description Voltage Part No.
LAC EXTREME-115-60-UL 110 - 120 V, 60 Hz 4679284
LAC EXTREME-230-60-UL 208 - 240 V, 60 Hz 4679292

Download:   > Manual


Inverter_Check_Kit

INVERTER CHECK KIT

The INVERTER CHECK KIT is an invaluable test kit for the analysis of problems solving with inverted-fed air conditioners. Designed to be used both in installation and maintenance, this kit can indicate correctly operating inverter power stages, as well as the serial-link communication between the condensing unit and the indoor units. This allows the air conditioning engineer to easily identify faults and reduces the time required for analysis and repair. The kit contains the electronic module with a set of leads as well as a selection of cables.

Part No. 4678571

Download:  
> Manual


Messbereich: Atm. bis 50 Mikron = 0,06 mb
Messbereich: Atm. bis 50 Mikron = 0,06 mbar
In-line_Filter

IN-LINE FILTER for Sahara and Yuma

The IN-LINE FILTER fits in the drain line from an air conditioner to its condensate pump, and should be used wherever dirt particles, construction debris, hairs or greasy deposits can be washed from the drain tray down into the pump.

 


Part No. 4678597


Download:   > Manual